Michael Karl McNeil: night work in the fields and the light meter under Section 3449

My name is Michael Karl McNeil. I spent twenty-five years in the fire service, finished as a Fire Battalion Chief, and now consult on workplace safety and industrial hygiene. Most of the standards I work with can be answered with a document: a written program, a training roster, a signed inspection. Title 8, Section 3449 cannot. It governs outdoor agricultural operations during the hours of darkness, between sunset and sunrise, and the only way to show compliance with its core requirement is to stand in the field with a light meter.

A first of its kind

Section 3449 and its appendix were filed in June 2020 and became operative on July 1, 2020. California was the first state in the country to adopt a standard written specifically for night work in agriculture. It is short, and it has no separate definitions subsection and no training requirement beyond the shift meeting described below. What it does have is a table of illumination levels that most crews have never seen.

The light levels are set by task, not by site

Table 1 of the section does not assign one number to a farm or a field. It assigns a number to each operation, area or task, so a single crew working one field can owe four different levels at the same moment:

  • 0.09 to 0.19 foot-candles (1 to 2 lux) for poultry harvesting or catching.
  • 3 foot-candles (32.29 lux) for the meeting area and the meal and rest area.
  • 5 foot-candles (53.82 lux) for outdoor agricultural operations generally, for the pathways to and around restrooms and drinking water, inside restroom facilities, and in storage areas employees enter.
  • 10 foot-candles (107.64 lux) for intermittently or exposed point-of-operation equipment, for operationally visible moving parts of machinery, and as task lighting for tools that can cut, lacerate or puncture.
  • 20 foot-candles (215.30 lux) as task lighting for maintenance work on equipment.

Two measurement heights, and they are not interchangeable

Task lighting is measured at the task or working surface. Area lighting is measured about 30 inches above the floor or other surface employees walk on, work on or access. A single convenient reading taken at chest height in the middle of a row answers neither question. When I check a night operation, the readings go on a sketch of the field with the height noted beside each one, because that is the only record that shows the table was actually met.

The light can come from lamps mounted on equipment or vehicles, from hands-free portable personal lighting, or from a combination. The employer has to provide and maintain hands-free personal lighting, area lighting, or both. Maintain is the working word: a headlamp with a dead battery at two in the morning is the employer's failure, not the worker's.

More light is not automatically compliant

The section's own note directs that area lighting minimize glare through lamp selection, shielding, beam-angle adjustment or glare-avoidance screens. It also carries an exception worth knowing: additional lighting installed to meet Table 1 does not have to be switched on while vehicles travel on farm roads, so that drivers are not blinded. A crew that floods a field road with work lights to be safe can create the very hazard the standard is trying to prevent.

The shift meeting

At the start of each shift, a supervisory employee holds a safety meeting covering where the restrooms, drinking water and designated break areas are, along with any nearby bodies of water and high-traffic areas. The section ties that meeting to Section 3203(a)(3), the Injury and Illness Prevention Program, which is where the documentation duty sits. A meeting held and not written down is a meeting the employer will have trouble proving.

Class 2 high-visibility garments

For work between sunset and sunrise, the employer provides, and requires workers to wear, Class 2 high-visibility garments meeting Section 3380(e) and ANSI/ISEA 107-2015, which the section incorporates by reference. Class 2 is the floor. A Class 1 vest, the lighter garment some crews keep in the truck, does not satisfy it.

What to have ready

If a night operation is inspected, the questions will be practical. Which Table 1 level applies to each task you are running tonight? Where and at what height were the readings taken? Who held the shift meeting, and where is it recorded? Are the garments Class 2? None of that is answered by a binder in the office. It is answered in the field, with the meter in hand.

Michael Karl McNeil, REP, RIH, EPP, QSD — McNeil Safety Consulting, (626) 546-9384, mcneilsafetyconsulting.com. This post summarizes the regulation for general information; read the current text of 8 CCR 3449 for the governing language.

Comments

Popular posts from this blog

Rebutting the serious-violation presumption under Labor Code 6432

Cal/OSHA Noise Exposure: The 85-Decibel Line That Starts a Hearing Conservation Program — Michael Karl McNeil

Labor Code 6317: the six-month clock runs from the violation, not the inspection